Description:
Designed in accordance with Inshore and Offshore requirements outlined in ADC, HSE, IMCA D040 & D015 and OGP guidelines the package is supplied with HP air storage mounted in a mild steel frame, with lifting points and engraved stainless steel panel fascia. There are 4 x 50 Litre 300 Bar cylinders mounted inside the protective crash frame creating 3 regulated air supplies; Primary HP to Diver 1, Primary HP to Diver 2 and a common Secondary HP fully distributed, regulated and indicated via 63mm pressure gauges each with emergency isolation valves. Above the cylinders are removable trident racks for Umbilical storage.
Divers are monitored by 150mm Diameter depth gauges with a range of 0-70 MSW (0-230 FSW) in 0.5 MSW increments complete with calibration point. Panel has been designed to comply with the requirements set by respected helmet manufacturers. All pressure gauges are dry, cleaned and certified for use with breathing quality air. The system is supplied fully certified, calibrated and complete with supporting documentation to IMCA D018
Specification:
Dimensions: 650 mm wide x 2150 mm length x 1465 mm high
Approximate weight: 500 kg
Connections:
· Inlets: HP Charging - 4 JIC
· Outlets: Divers Supply - 6 JIC
· Divers Pneumo - 4 JIC
Optional Extras:
· Diver Communications
· Diver Umbilical's
· Diver CCTV